Ideal Logic Combi 24 User Guide ‒ Article Plan
This comprehensive guide details the features, safe operation, and troubleshooting of your Ideal Logic Combi 24 boiler, ensuring optimal performance and longevity for years to come․

Welcome to the world of efficient home heating! The Ideal Logic Combi 24 is a highly reliable and efficient condensing combination boiler, designed to provide both central heating and on-demand hot water for your home․ This user guide is crafted to help you understand and operate your boiler safely and effectively, maximizing its performance and lifespan․
This boiler is known for its compact design, ease of installation, and user-friendly controls․ Whether you’re a first-time boiler owner or familiar with central heating systems, this manual will provide clear instructions and valuable insights․ We’ll cover everything from initial setup and daily operation to troubleshooting common issues and scheduling routine maintenance․
Remember, prioritizing safety and following the guidelines outlined in this manual are crucial for ensuring the long-term reliability of your Ideal Logic Combi 24․
Safety Precautions
Your safety is paramount․ The Ideal Logic Combi 24 operates using natural gas and high temperatures, requiring strict adherence to safety guidelines․ Always prioritize safety when installing, operating, and maintaining this appliance․ Never attempt repairs yourself; only qualified, authorized engineers should perform servicing or repairs․
Crucially, be aware of the risks of carbon monoxide poisoning․ Ensure you have a working carbon monoxide detector installed in a central location near the boiler․ Familiarize yourself with the symptoms of carbon monoxide exposure․ Use only genuine Ideal spare parts to maintain the boiler’s safety features and performance specifications․
Do not obstruct ventilation pathways or tamper with safety devices․ Regularly check for gas leaks and report any concerns immediately to a qualified professional․ This boiler is designed for indoor use only․

General Safety Warnings
Exercise extreme caution when operating the Ideal Logic Combi 24․ This appliance reaches high temperatures and involves potentially hazardous gases․ Never operate the boiler with damaged components or altered safety features․ Keep flammable materials well clear of the boiler’s vicinity to prevent fire hazards․
Always supervise children and vulnerable individuals around the boiler․ Ensure they understand the dangers associated with hot surfaces and potential gas leaks․ Do not use the boiler in enclosed spaces without adequate ventilation․ Regularly inspect the flue for blockages or damage, as this can lead to carbon monoxide buildup․
If you smell gas, immediately shut off the gas supply and contact a qualified gas engineer․ Do not operate any electrical switches, as this could ignite the gas․
Carbon Monoxide Risks
Carbon monoxide (CO) is a deadly, odorless, and colorless gas produced by incomplete combustion․ The Ideal Logic Combi 24, like all gas appliances, carries a risk of CO production if not properly maintained or ventilated․ Install a certified CO detector near the boiler and in living areas, ensuring it’s regularly tested and has fresh batteries․
Symptoms of CO poisoning include headache, dizziness, nausea, fatigue, and confusion․ If anyone experiences these symptoms, immediately evacuate the premises and call emergency services․ Never ignore suspected CO poisoning․
Ensure the flue is unobstructed and correctly fitted to vent exhaust gases safely outside․ Annual servicing by a qualified engineer is crucial to detect and prevent CO leaks․ Do not attempt to repair or modify the boiler yourself․
Boiler Overview & Components
The Ideal Logic Combi 24 is a compact and efficient combination boiler, providing both central heating and domestic hot water on demand․ Understanding its key components is vital for safe operation and maintenance․ The boiler casing houses the heat exchanger, burner, fan, and control unit․
Essential external features include the control panel for adjusting settings, the pressure gauge to monitor system pressure, and connections for gas, water, and flue․ The flue system safely vents combustion gases outside․ Regularly inspect these components for any signs of damage or corrosion․
Proper functioning relies on all parts working harmoniously․ Only qualified engineers should attempt repairs or replacements, using authorized Ideal spare parts to maintain safety and performance standards․
Identifying Key Parts
Locating the essential components of your Ideal Logic Combi 24 is crucial for understanding its operation․ The heat exchanger transfers heat to the water, while the burner ignites the gas․ The fan provides airflow for combustion, and the pump circulates water through the system․
Externally, identify the control panel with its display and buttons, the pressure gauge indicating system pressure, and the filling loop used to top up water levels․ The gas connection supplies fuel, and the flue outlet vents exhaust gases․
Familiarize yourself with these parts; however, remember that internal components should only be accessed by qualified service engineers․ Using only authorized Ideal spare parts is paramount for safety and performance․

Control Panel Explanation
The Ideal Logic Combi 24’s control panel is your interface for operating the boiler․ The digital display shows current temperature settings, error codes, and timer information․ Buttons allow you to adjust heating and hot water temperatures, and to navigate the electronic timer functions․
Key symbols indicate power status, heating demand, hot water activation, and any fault conditions․ Understanding these symbols is vital for interpreting the boiler’s status․ The panel also facilitates setting the operating mode – comfort, eco, or off․
Refer to the manual for specific button functions and error code explanations․ Proper use of the control panel ensures efficient and safe operation of your heating system, maximizing comfort and minimizing energy consumption․
Initial Setup & Commissioning
Before first use, proper initial setup and commissioning are crucial for optimal performance․ This involves verifying the boiler’s installation adheres to current regulations and manufacturer guidelines․ Ensure a qualified Gas Safe registered engineer performs this stage․
Key steps include checking gas supply pressure, verifying flue integrity, and confirming correct electrical connections․ System filling with water to the correct pressure is essential, followed by bleeding the radiators to remove trapped air․
Commissioning also involves setting the correct boiler parameters, such as gas rate and temperature limits, tailored to your heating system․ Thorough testing confirms functionality and safety before regular operation begins․
Filling the System
Proper system filling is vital before the initial start-up and after any significant water loss․ Locate the filling loop – typically two flexible hoses connecting the boiler’s filling loop valve to the heating system pipework․ Ensure the system valves are in the open position․
Slowly open the filling loop valves to allow water into the system, monitoring the boiler’s pressure gauge․ The ideal pressure is usually between 1 and 1․5 bar (check your boiler’s specific requirements)․ Close the filling loop valves once the correct pressure is reached․
Be cautious not to over-pressurize the system․ If over-pressurization occurs, carefully open a radiator bleed valve to release excess pressure․ Regularly check the pressure and top up as needed․
Bleeding the Radiators
Air trapped in radiators can reduce heating efficiency․ Begin with the radiators furthest from the boiler․ Using a radiator key, slowly open the bleed valve – typically located at the top side of the radiator․ Listen for the hiss of escaping air․
Once water starts to emerge, tighten the bleed valve to prevent leaks․ Repeat this process for each radiator in your system, working your way closer to the boiler․ Monitor the boiler’s pressure; bleeding radiators can lower system pressure․
If the pressure drops below 1 bar, refill the system as described in the ‘Filling the System’ section․ Regularly bleeding radiators ensures optimal heat output and a quieter heating system․
Operating the Boiler ‒ Basic Functions
Powering on the Ideal Logic Combi 24 is straightforward; locate the power switch, usually on the front panel, and toggle it to the ‘on’ position․ The control panel will illuminate, indicating the boiler is active․ To power off, simply reverse this process․
Setting the desired temperature is achieved via the control panel’s up and down buttons․ The current and target temperatures are displayed digitally․ Adjust to your comfort level, remembering that lower temperatures save energy․
The boiler automatically adjusts to maintain the set temperature, providing both heating and hot water on demand․ Familiarize yourself with the indicator lights to understand the boiler’s current status․

Powering On/Off
Initiating the Ideal Logic Combi 24 involves locating the primary power switch, typically situated on the boiler’s front panel․ Gently toggle this switch to the ‘I’ or ‘On’ position․ Observe the control panel; it should illuminate, confirming the boiler is receiving power and initiating its startup sequence․
To safely shut down the boiler, reverse the process․ Return the power switch to the ‘O’ or ‘Off’ position․ The control panel display will darken, indicating the boiler is no longer operational․
Ensure the boiler is fully powered off before undertaking any maintenance or inspection․ Avoid interrupting the power cycle during operation, as this could potentially affect performance․

Setting the Temperature
Adjusting the desired room temperature on your Ideal Logic Combi 24 is straightforward․ Utilize the up and down arrow buttons located on the control panel․ Each press incrementally increases or decreases the target temperature, displayed clearly on the screen․
The boiler supports precise temperature control, allowing you to fine-tune the heating to your comfort level․ Observe the current room temperature, often displayed alongside the setpoint, to gauge the heating system’s performance․
For optimal efficiency, avoid excessively high temperature settings․ Consider utilizing the timer function to schedule temperature adjustments based on occupancy and daily routines․
Using the Electronic Timer
The electronic timer on your Ideal Logic Combi 24 offers convenient control over your heating schedule․ Access the timer settings through the control panel’s menu, typically navigated using the selector button and arrow keys․
Programming the timer allows you to define specific on/off periods for heating throughout the day and week․ Different timer modes are available, including pre-set programs and fully customizable schedules․ Understanding these modes is crucial for efficient operation․
Utilize the timer to reduce energy consumption by ensuring heating is only active when needed, maximizing comfort and minimizing bills․ Regularly review and adjust the timer settings to align with your lifestyle․

Programming the Timer
To program the timer on your Ideal Logic Combi 24, first enter the timer mode via the control panel․ Use the selector button to navigate to ‘Program’ or ‘Timer’ and confirm your selection․ Then, set the desired start time for each heating period, followed by the end time․
Repeat this process for each day of the week, or utilize the ‘Copy Day’ function to replicate settings across multiple days․ Consider creating different programs for weekdays and weekends to match your routine․
Remember to save your changes after programming․ Experiment with different schedules to find the optimal balance between comfort and energy efficiency․
Understanding Timer Modes
The Ideal Logic Combi 24 timer offers several modes to suit your heating needs․ ‘Program’ mode allows for fully customized schedules, setting specific on/off times for each day․ ‘Manual’ mode overrides the program, providing continuous heating or hot water until manually switched off․
‘Holiday’ mode is ideal for extended absences, maintaining a frost protection temperature to prevent pipe freezing․ ‘Eco’ mode optimizes energy usage by reducing heating output during certain periods․
Familiarize yourself with each mode’s function to maximize efficiency and comfort․ The control panel display will indicate the currently selected mode․ Switching between modes is typically done using the selector and confirmation buttons․
Troubleshooting Common Issues

Encountering problems with your Ideal Logic Combi 24? This section addresses frequent concerns․ No heating or hot water often indicates low pressure, a locked-out boiler, or a gas supply issue – check the pressure gauge and reset the boiler if necessary․ Low pressure problems can be resolved by re-filling the system, following the instructions in the ‘Initial Setup’ section․
Error codes displayed on the control panel provide valuable diagnostic information; consult the full manual for specific code meanings․ Frozen condensate pipes in winter can cause issues – ensure they are free from ice․ If problems persist, always consult a qualified heating engineer․
No Heating or Hot Water
Experiencing a lack of heating or hot water from your Ideal Logic Combi 24? First, check the boiler’s pressure gauge; low pressure is a common culprit․ If the pressure is too low, refer to the ‘Filling the System’ section to repressurise it․ Verify the boiler is powered on and hasn’t entered a lockout state – attempt a reset․
Ensure the thermostat is calling for heat and set to a temperature above the current room temperature․ Inspect the gas supply; a disrupted supply will prevent operation․ Look for any error codes displayed on the control panel, as these offer clues to the problem․ If these steps fail, contact a qualified heating engineer for assistance․
Low Pressure Problems
Consistently low pressure on your Ideal Logic Combi 24 can indicate a leak within the central heating system․ Regularly check the pressure gauge – ideally, it should sit between 1 and 1․5 bar․ If the pressure frequently drops, carefully inspect all visible pipework, radiators, and connections for signs of water leakage․ Bleeding radiators can sometimes temporarily lower pressure, requiring a top-up․
To repressurise the system, follow the ‘Filling the System’ instructions․ Avoid repeatedly topping up without identifying and fixing the underlying leak; If you are unable to locate the leak or the pressure continues to fall, it’s crucial to contact a qualified heating engineer to diagnose and repair the issue promptly, preventing potential damage․
Maintenance & Servicing
Regular maintenance is vital for the efficient and safe operation of your Ideal Logic Combi 24 boiler․ Perform monthly visual checks for any leaks or corrosion around the unit and pipework․ Ensure the flue is unobstructed and free from debris․ Periodically check the pressure gauge, maintaining it within the recommended 1-1․5 bar range, and top up if necessary;
However, these checks are not a substitute for professional servicing․ An annual service by a Gas Safe registered engineer is essential․ Servicing includes a thorough inspection of all components, cleaning, and safety checks, ensuring optimal performance and identifying potential issues before they escalate․ Using only authorised spare parts is crucial for maintaining boiler integrity and warranty validity․
Regular Checks
To ensure optimal performance and longevity of your Ideal Logic Combi 24, implement routine visual inspections․ Monthly, check for any signs of leaks around the boiler casing, pipe connections, and the pressure relief valve․ Inspect the flue terminal, ensuring it’s clear of obstructions like leaves or bird nests – a blocked flue poses a serious safety risk․

Monitor the boiler’s pressure gauge; it should ideally sit between 1 and 1․5 bar․ If the pressure is consistently low, investigate potential leaks․ Visually examine the heat exchanger (if accessible and safe to do so) for any signs of corrosion․ Remember, these are basic checks and do not replace the need for annual professional servicing by a qualified Gas Safe engineer․
Importance of Annual Servicing
Annual servicing by a Gas Safe registered engineer is crucial for maintaining the safety and efficiency of your Ideal Logic Combi 24․ A qualified technician will perform a comprehensive inspection, including a flue gas analysis to ensure complete combustion and minimize carbon monoxide risk․ They’ll meticulously check all components, identifying and addressing potential issues before they escalate into costly repairs․
Servicing ensures compliance with warranty requirements and optimizes boiler performance, potentially reducing energy consumption․ The engineer will clean vital parts, like the burner and heat exchanger, improving efficiency․ Don’t attempt to service the boiler yourself; it requires specialized knowledge and tools․ Prioritize safety and longevity – schedule your annual service today!

Spare Parts & Authorised Replacements
When replacing any component within your Ideal Logic Combi 24, it’s absolutely vital to use only genuine Ideal spare parts․ Using non-authorised or reconditioned parts can compromise the boiler’s safety, performance, and warranty validity․ Ideal specifically advises against using copy parts that haven’t received their explicit approval․
Genuine parts are engineered to meet stringent safety and performance specifications, ensuring seamless integration and optimal operation․ Sourcing from authorised suppliers guarantees quality and compatibility․ Contact a qualified heating engineer or an official Ideal parts distributor to obtain the correct replacement․ Prioritizing genuine parts safeguards your investment and maintains the boiler’s reliability․